Comparison of a new immobilization method using a reusable 3‐point fixation cylinder system and bite‐block type immobilization methods in veterinary radiotherapy

https://az.repo.nii.ac.jp/records/2000528
https://az.repo.nii.ac.jp/records/2000528
e3af18f5-184b-4a82-807f-2f5f8ca85e2e
名前 / ファイル ライセンス アクション
VRU-09-23-147.R3_Proof_hi.pdf VRU-09-23-147.R3_Proof_hi.pdf (1.9 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2026-02-25
タイトル
タイトル Comparison of a new immobilization method using a reusable 3‐point fixation cylinder system and bite‐block type immobilization methods in veterinary radiotherapy
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yoda, Shinichiro

× Yoda, Shinichiro

en Yoda, Shinichiro

Search repository
Maruo, Takuya

× Maruo, Takuya

en Maruo, Takuya

Search repository
Arai, Haruka

× Arai, Haruka

en Arai, Haruka

Search repository
Takahashi, Rihoko

× Takahashi, Rihoko

en Takahashi, Rihoko

Search repository
Kusaka, Takuya

× Kusaka, Takuya

en Kusaka, Takuya

Search repository
Nishiyama, Yuta

× Nishiyama, Yuta

en Nishiyama, Yuta

Search repository
Kayanuma, Hideki

× Kayanuma, Hideki

en Kayanuma, Hideki

Search repository
Abstract
内容記述タイプ Abstract
内容記述 In veterinary radiotherapy, highly reproducible immobilization is important for accurate irradiation. Consequently, we developed a new reusable head-immobilization method for dogs using cylinders. This study aimed to compare the accuracy of our novel immobilization method using cylinders with that of bite-block type immobilization methods. Three immobilization methods were compared: bite-block only, bite-block combined with torso immobilization, and immobilization using cylinders. Five beagles with canine teeth underwent CT five times for each of the three immobilization methods. One beagle without canine teeth underwent CT 15 times using each method. Three maxillary landmarks (maxillary incisor, frontal sinus, and occipital bone) and one mandibular landmark (mandibular incisor) were established, and the errors in each immobilization method were measured. For all head landmarks, the error in the immobilization method using cylinders was the most reproducible, with the smallest errors. No significant differences were observed in the time required for immobilization. Although there were limitations (such as the use of dogs from a single breed, a single episode of anesthesia, no disassembly of the immobilization system between scans, and the same person performing the positioning on the same day), we found our new reusable immobilization method using cylinders was the most accurate among the three compared methods. This was a proof-of-principle study to evaluate head immobilization using cylinders, and further investigations are needed to confirm its clinical utility.
言語 en
書誌情報 Veterinary Radiology & Ultrasound

巻 65, 号 4, p. 323-333, 発行日 2024-03-30
出版者
出版者 Wiley
DOI
識別子タイプ DOI
関連識別子 10.1111/vru.13364
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
査読
内容記述タイプ Other
内容記述 査読あり
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-12 02:31:42.359316
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3